12KV Switchgear Compact Substation
12KV Switchgear Compact Substation
Mingrui has outstanding technical researching team and superior equipments, specially concentrate on research & development, production, sales and service of neutral grounding series products of power distribution system. The transformer neutral grounding resistance cabinet we developed and produced is applicable to 6~35KV power distribution grid of cable running lines in cities, large industrial enterprises, factories, airports, seaports, subway and etc. as well as 0.66KV system in mine digging and 0.4kv/6kv/10kv system in power plants.
Standards Carried Out
DL/780-2001 Neutral Grounding Resistance in Power Distribution
GB6450 Dry-Type Power Transformer
DL/T620-1997 Overvoltage Protection and Insulation Co-ordination of AC Electrical Equipments
GB/T16927-1997 Experimental Technique of High Voltage
GB1208-1997 Current Transformer
GB4208-93 Shell Protection Grade (IP code)
IEEE32-1972 Standard Technique, Terms and Experiment of Neutral Grounding Device
GB311.1-1997 Insulation Co-ordination of Transmissional and Distributed Device of High Voltage.
DL/T593-1996 Common Specifications for Purchasing High Voltage Switch Equipment.
GB50150-1991 Electrical Equipment’s Hand-over and Test Standard of Electrical Device Installation Project.
Product Features
Typical Technical Parameters in Some Cases | ||||||
Model No | System Voltage (kv) | Rated Voltage (kv) | Current Flowing Time (s) | Rated Resistance (ohms +-5%) | Inslutaion Withstanding Voltage kv | |
8/20 µs Linghtning Strike | 1 min PF Voltage | |||||
MRD-BJ-6/36.4 | 6.3 | 100 | 10 | 36.4 | 60 | 32 |
MRD-BJ-6/18.2 | 6.3 | 200 | 10 | 18.2 | 60 | 32 |
MRD-BJ-6/9.09 | 6.3 | 400 | 10 | 9.09 | 60 | 32 |
MRD-BJ-6/6.06 | 6.3 | 600 | 10 | 6.06 | 60 | 32 |
MRD-BJ-10/15.16 | 10.5 | 400 | 10 | 15.16 | 75 | 42 |
MRD-BJ-10/10.10 | 10.5 | 600 | 10 | 10.1 | 75 | 42 |
MRD-BJ-10/7.57 | 10.5 | 800 | 10 | 7.57 | 75 | 42 |
MRD-BJ-10/6.06 | 10.5 | 1000 | 10 | 6.06 | 75 | 42 |
MRD-BJ-35/20.20 | 35 | 1000 | 10 | 20.2 | 185 | 95 |
MRD-BJ-35/10.10 | 35 | 2000 | 10 | 10.1 | 185 | 95 |
Various NGRs could be designed as per customers' need with resistance from 1-2000ohms,current from 1-2000A and time at 10s, 15s, 30s, 60s or 2h. |
Main Composed Elements | |
Resistor | made of imported stainless steel or domestic stainless steel, high conductivity and temperature coefficient,corrosion resisting, thermostability, operation safty |
Grounding Transformer | Optional, if tansformer is angle-connected, grounding transformer should be used. |
Counter | Optional, for recording grounding times of NGR |
Disconnector | Optional, for convenienting maintainance |
Heater and Humidity Controller | Optional |
Monitor | Optional, for monitoring unbalanced current, temperature of resistor and cabinet inside, grounding fault current and grounding times when single phase grounding.And transfering the datas to main controlling room. |
Operation Conditions
1. Mostly applied outdoor in system of 50Hz and 60Hz
2. Max Altitude is 3500m. Because of high altitude and bad thermal discharging in plateau, please indicate in order if in this situation.
3. Ambient Temp is between -20°C~+70°C and relative humidity does not excess 95%.
4. Wind pressure does not excess 700Mpa (equivalent to 34m/s)
5. Earthquake intensity is less than 8 degree.
6. Thickness of ice coverage is less than 10mm
7. Air dusty grade is not higher than IV grade
8. No corrosive or explosive gas and conductive dust around installation site.
9. As the resistor is a heat generating component, it should be installed in place with some space left around, and be away from heat source.
Notice for purchase
1. system rated voltage
2.short-time withstand current;
3. normal resistance;
4. with current transformer or not; transformation ratio, capacity and compound deviation of the current transformer;
5. method of wiring (optional): a. wire in from the top, and out at the bottom, b. wire in and out from the bottom, c. wire in and out from the side, d. wire in from the side and out at the bottom;
6. durable time for short-time withstand current;
7. material of resistance cabinet, protection grade of (IP), color code and installation site of the resistor cabinet;
8. with earthing record and temperature and humidity control equipment or not
12KV Switchgear Compact Substation